HUB on Campus – Raleigh is a high-rise student housing development located at 111 Cox Avenue in Raleigh, North Carolina. The building integrates INTUS energy-efficient window systems developed to meet thermal, acoustic, and structural performance requirements in multi-unit residential applications.

The windows are double-glazed with 22mm and 24mm thick annealed and tempered glass. The system provides a U-value of 0.25, SHGC of 0.24, and visible transmittance of 0.61. Air infiltration is rated at 0.1 cfm/ft², water penetration resistance at 7.52 psf, and design pressure at ±50.13 psf.

Acoustic performance is rated STC 32 / OITC 26. Windows are installed using a receptor system and mounting brackets.

111 Cox Ave, Raleigh, NC 27605, USA —
Show on map
Student Housing
2920
planted
One Window One Tree
PRODUCTS
Products Used in the Project
Windows
Doors
Glass
Handles
Limiters
Ext Trim
Addtl Accy
Supera CW Window
cw
Colors used in the project
Exterior
Black Smooth
Interior
White
PROJECT TECHNICAL SPECIFICATION
Superior energy efficiency with INTUS products
Building Size
High Rise
Installation Type
Receptor System, Mounting Brackets
U-value
0.25
SHGC
0.24
Visual Transmittance
0.61
Air Infiltration
0.1 cfm/ft2
Water Penetration
7.52 psf
Design Pressure
±50.13 psf
Sound Performance
STC 32 / OITC 26